ULTIMO Lithium Ion Capacitor Laminate Cell Module

Making maximum benefit of the characteristics of ULTIMO cells, ULTIMO modules are designed to be used in a convenient and safe way. They can be used in various applications such as backup, storage, peak assist, and energy regeneration.

Furthermore, these modules are energy-efficient and extremely safe products equipped with low-power-consuming cell voltage balancing circuits, as well as detection circuits to prevent overcharge and over-discharge.

ULTIMO modules can be used in series and in parallel configurations.

Please contact us for custom made module inquiries and system solutions.

Product code Cell type Voltage range Capacitance Contents Size in mm
(WxDxH)
MLB15G275D Laminate type 8.8 V - 15.2 V 275 F CLQ1100S1A, 4 cells 152.0x267.2x105.1
MLB15G550F 550 F CLQ2200S2A, 4 cells 152.0x267.2x123.7
MLB30G138D 17.6 V - 30.4 V 138 F CLQ1100S1A, 8 cells 152.0x267.2x142.3
MLB30G275F 275 F CLQ2200S2A, 8 cells 152.0x267.2x185.7
MLB45G92D 26.4 V - 45.6 V 92 F CLQ1100S1A, 12 cells 152.0x267.2x179.5
MLB45G184F 184 F CLQ2200S2A, 12 cells 152.0x267.2x247.7
MPA15G575G Prismatic type 8.8 V - 15.2 V 575 F CPQ2300S, 4 cells 168.8x127.1x112.5
MPA15G825H 825 F CPP3300S, 4 cells 168.8x127.1x112.5
MPA30G288G 17.6 V - 30.4 V 288 F CPQ2300S, 8 cells 168.8x127.1x186.5
MPA30G413H 413 F CPP3300S, 8 cells 168.8x127.1x186.5
MPA45G192G 26.4 V - 45.6 V 192 F CPQ2300S, 12 cells 168.8x127.1x260.5
MPA45G275H 275 F CPP3300S, 12 cells 168.8x127.1x260.

* The information herein may change without prior notice    

Characteristic Description Note
Charge/discharge current (maximum rating) 360 A  
Module control method CPU program control  
Balancing method Resistance discharge method  
Monitoring function Voltage monitoring  
Temperature monitoring  
Control signal Output signal Alarm signal for over charge 1. No charge/discharge cut-off function by alarm
2 Only one alarm for over discharge
Alarm signal for over discharge
Alarm signal for exceeding temperature range
Input signal Wake up requirement signal Internal self-timer operation when not in use
Sleep requirement signal
Electricity consumption of controller Less than 20%u03BCA at sleep mode  
Inter module Voltage balancing 12 units (maximum series) External controller need for 5 or more in series
Environmental conditions Operating temperature -30C - 70C Depends on usage conditions
Operating humidity range 20% - 90% RH (no dew consent)C

* The information herein may change without prior notice